Editorial Opinions

Editorial – Issue 071 March 2025

The Evolution of Synchrophasors

by Alex Apostolov, Editor-in-Chief

This image has an empty alt attribute; its file name is image.YM7RH1-e1644660671454.png

Synchrophasor technology represents one of the most significant advancements in modern power system monitoring and control. From humble beginnings to becoming an essential component of smart grid infrastructure, synchrophasors have revolutionized how utilities manage electrical networks worldwide.

The concept of synchrophasors emerged in the 1980s when Dr. Arun G. Phadke and Dr. James S. Thorp at Virginia Tech pioneered the development of phasor measurement units (PMUs). These devices measure voltage and current phasors with precise time synchronization, providing a comprehensive snapshot of power system conditions. Prior to this innovation, system operators relied on supervisory control and data acquisition (SCADA) systems that offered only limited visibility into grid behavior.  

The first commercial PMU was introduced in 1988, but widespread adoption was initially constrained by high costs and limited communications infrastructure. Early implementations primarily served research purposes, with only a handful of units deployed in utility systems. I was lucky to witness this in the early 1990s while working at New York State Electric & Gas.

This was a period of significant advancements in synchrophasor technology. The IEEE developed the first standard for synchrophasor measurements (IEEE 1344) in 1995, later superseded by IEEE C37.118, which established uniform requirements for measurement accuracy and data formats. These standards facilitated interoperability between devices from different manufacturers.

Bonneville Power Administration (BPA) emerged as an early adopter, implementing synchrophasor technology in the early 1990s. Their pioneering work demonstrated the practical value of PMUs for grid monitoring and helped establish operational protocols that would later be adopted industry wide.

The technology’s evolution accelerated with improvements in GPS time synchronization, which enhanced measurement precision to microsecond accuracy. Simultaneously, data processing capabilities expanded, enabling the analysis of larger datasets at faster rates. Modern PMUs can sample at rates of 30-120 measurements per second, dramatically surpassing traditional SCADA systems that typically collect data every 2-4 seconds.

The 2003 Northeast blackout in the United States was a critical moment for synchrophasor adoption. This massive outage, affecting approximately 55 million people and highlighted significant gaps in grid monitoring capabilities. Subsequent investigations recommended wider implementation of synchrophasor technology to improve situational awareness and prevent cascading failures.

In response, the U.S. Department of Energy launched the Smart Grid Investment Grant program following the 2008 economic crisis, allocating significant funding to synchrophasor projects. This initiative dramatically increased PMU deployment across North America, expanding from fewer than 200 units in 2009 to over 2,000 by 2015. Asia and Europe also invested in large-scale deployment to enhance grid resilience.

The application of synchrophasor technology has enabled numerous applications that transform grid operations. Based on it we can identify potentially dangerous power oscillations in real-time, allowing operators to take corrective actions before instabilities cascade into widespread outages. Synchrophasors provide direct measurements of system state, enabling more accurate and faster state observation compared to traditional state estimation methods. High-resolution PMU data offers unprecedented insight into system disturbances, allowing engineers to reconstruct event sequences with millisecond precision. Synchrophasor measurements help validate and refine power system models, improving simulation accuracy for planning and operational studies. P-class synchrophasors support and enhance the effectiveness of system integrity protection schemes designed to maintain system stability during contingencies. They can also be used in different protection applications.

Recent developments include cloud-based platforms for PMU data sharing, enabling collaborative analysis across organizational boundaries. These systems leverage modern computing infrastructure to provide scalable, secure environments for storing and processing massive synchrophasor datasets.

As power systems evolve to accommodate more renewable energy sources and distributed generation, synchrophasor technology continues to adapt. Current research focuses on applying artificial intelligence and machine learning to PMU data for predictive analytics and automated control applications.

The journey of synchrophasor technology from academic concept to essential grid infrastructure illustrates how technological innovation can fundamentally transform critical infrastructure management. Today’s smart grid, with its enhanced situational awareness and dynamic control capabilities owes much to this evolution—a testament to engineering innovations addressing the complex challenges of modern power systems.

Steve Jobs